Start-up Procedure
1. Connect the air power source with the Air
(A) line.
2. Make sure the hydraulic reservoir is full.
3. Connect the hydraulic Pressure (P), Tank
(T) and Air (A) lines. "P" and "T" Port
Designations are stamped on the Main
Hydraulic Manifold (M).
4. Check for hydraulic leaks. If leaks occur,
see Trouble Shooting, p. 67.
5. No motion should occur. If there is
movement of any parts on the HawkJaw,
see Trouble Shooting, p. 67-69.
Operation14
NOTE
Tightly connect the hose fittings. A
loose connection causes a pressure drop
in the hydraulic fluid which heats up the
fluid and reduces component life.
Part Numbers
Part Name Part #
Male Quick Disconnect (P) 061-H52
Female Quick Disconnect (T) 061-H53
Male Air Quick Disc. (A) 061-A12M
Female Air Quick Disc. 061-A12F
A
M
P
T
Commentaires sur ces manuels