Winch Hook - Up
14 Installation
1. Connect the air power source
with the Air (A) line.
2. Make sure the hydraulic
reservoir is full.
3. Connect the hydraulic Pressure
(P) and Tank (T) lines. The
Pressure line (P) Quick
Disconnect is male.
4. Make sure the "E" stop (E) is
pulled out.
5. Check for hydraulic leaks. If
leaks occur, see Trouble
Shooting.
6. With the exception of the hooks
retracting, no motion should
occur. If any other parts on the
HawkJaw move, see Trouble
Shooting.
Part Numbers
Part Name Part #
Male Quick Disconnect (P) 061-H52
Female Quick Disconnect (T) 061-H53
Male Air Quick Disc. (A) 061-A12M
Female Air Quick Disc. 061-A12F
Continued on next page.
NOTE
Use only Hawk approved quick
disconnects.
P
T
A
E
NOTE
Tightly connect the quick disconnects.
A loose connection causes a pressure drop
in the hydraulic fluid which heats up the fluid
and reduces component life.