Trouble Shooting
Symptom Remedy
65
Troubleshooting
Continued on next page.
While torquing pipe, a desired
torque setting cannot be achieved
or the torque control valve will
not effect the torque output of
the Hawkjaw.
The Hawkjaw may have an obstructed tank lead-in
hose or quick disconnect. Clear the tank line ob-
struction and or tighten or replace tank line quick
disconnect.
Make sure the Low Torque Warning System pressure
and tank hoses are properly connected.
Hydraulic fluid heats up.
Check that the pump pressure compensator setting
is at 2600 psi. If the pump pressure compensator
setting is above the pressure relief valve setting on the
HawkJaw or the pressure relief valve setting on the
hydraulic power unit, the hydraulic fluid will heat up
rapidly.
There is a leak in the hydraulic system.
Check that the pump pressure compensator setting
is at 2600 psi. If the pump pressure compensator
setting is above the pressure relief valve setting on the
HawkJaw or the pressure relief valve setting on the
hydraulic power unit, the hydraulic fluid will heat up
rapidly.
There is a leak in the hydraulic system.
If there are no leaks in the hydraulic system, and the
pump pressure compensator setting is at 2600 psi on
a known, tested hydraulic power unit, and the hydrau-
lic power unit pressure relief valve is set above the
pump pressure compensator setting and the hydrau-
lic fluid still heats up, then the pressure relief valve
setting on the HawkJaw has been changed. The
pressure relief valve adjustment is set at Hawk Indus-
tries. Under no circumstances should this pressure
relief valve be adjusted. Adjusting the pressure relief
valve setting voids the warranty and can cause
severe damage to the HawkJaw and the hydraulic
power unit and shorten component life. However, if
this valve has been adjusted below 2600 psi, and the
pressure compensator setting is at 2600 psi, the
hydraulic fluid will pass over the pressure relief valve.
This will heat up the hydraulic fluid rapidly. Properly
set the pressure relief valve adjustment. On a